➔ Connector type DSUB 37-pin, male
All digital in- and outputs are available via a single DSUB connector.
If only digital inputs are used, there is no need for a 24V supply. Otherwise an external 24 supply must be connected to the pins 18, 19 & 37. In any case a ground wiring is required (pins 17 & 36).
In order to fulfill the requirements of the protection class IP65, an IP65 DSUB connector housing from FCT / Molex is required.
Connector DSUB37 for digital in- and outputs
Pin |
Description |
Note |
Pin |
Description |
Note |
---|---|---|---|---|---|
1 |
IN1 |
Input 1 |
20 |
OUT1 |
Output 1 |
2 |
IN2 |
Input 2 |
21 |
OUT2 |
Output 2 |
3 |
IN3 |
Input 3 |
22 |
OUT3 |
Output 3 |
4 |
IN4 |
Input 4 |
23 |
OUT4 |
Output 4 |
5 |
IN5 |
Input 5 |
24 |
OUT5 |
Output 5 |
6 |
IN6 |
Input 6 |
25 |
OUT6 |
Output 6 |
7 |
IN7 |
Input 7 |
26 |
OUT7 |
Output 7 |
8 |
IN8 |
Input 8 |
27 |
OUT8 |
Output 8 |
9 |
IN9 |
Input 9 |
28 |
OUT9 |
Output 9 |
10 |
IN10 |
Input 10 |
29 |
OUT10 |
Output 10 |
11 |
IN11 |
Input 11 |
30 |
OUT11 |
Output 11 |
12 |
IN12 |
Input 12 |
31 |
OUT12 |
Output 12 |
13 |
IN13 |
Input 13 |
32 |
OUT13 |
Output 13 |
14 |
IN14 |
Input 14 |
33 |
OUT14 |
Output 14 |
15 |
IN15 |
Input 15 |
34 |
OUT15 |
Output 15 |
16 |
IN16 |
Input 16 |
35 |
OUT16 |
Output 16 |
17 |
GND |
Ground for digital in- & outputs |
36 |
GND |
Ground for digital in- & outputs |
18 |
24V_In |
24V power supply (input) |
37 |
24V_In |
24V power supply (input) |
19 |
24V_In |
|
|
|